Re: bkbits.net is down

Mike Dresser (mdresser_l@windsormachine.com)
Fri, 27 Jun 2003 20:01:59 -0400 (EDT)


On Fri, 27 Jun 2003, Larry McVoy wrote:

> Anyone know what this means? This is from the supposedly superduper
> rackspace machine which has a Mylex SCSI RAID (see below):
>
> DAC960#0: Physical Device 0:0 Sense Data Received
> DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00
> DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000
> DAC960#0: Physical Device 0:0 Sense Data Received
> DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00
> DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000
> DAC960#0: Physical Device 0:0 Errors: Parity = 0, Soft = 0, Hard = 0, Misc = 0
> DAC960#0: Physical Device 0:0 Errors: Timeouts = 0, Retries = 0, Aborts = 0, Predicted = 0

3h - MEDIUM ERROR: indicates that the command terminated with a
non-recovered error caused by a flaw in the medium (the medium depends on
the device type)

Have to lookup the asc and ascq with ibm, as it varies by manufacturer.

0Bh 01h DTLPWRSOMCAE Warning - specified temperature exceeded

My guess is that you're seeing a temperature warning on a drive.

Which makes sense with the overheated server room.

Mike

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/